Powervault MD3060e

From FnordWiki
Jump to navigation Jump to search

4U tall. And space for 60 3.5inch (or 2.5inch) drives inside.

Attaching to the network

Each of the two rear mounted "enclousure management modules" ("EMMs") has a serial interface and an 8P8C modular jack for 100baseT Ethernet connectivity. The factory default IP addresses for these are 192.168.128.101 for EMM 0 (the top one) and 192.168.128.102 for EMM 1 (the bottom one). There is also a serial interface on each of the EMMs with a Mini-DIN 6 pin connector. Dell part numbers for the correct serial cables are CT109 and MN657. I have not used these and hope to not need them.

https://www.dell.com/support/kbdoc/en-us/000141824/pulling-logs-on-md3060e-via-serial-for-sds-solutions has some documentation on this.

Gather network config

From a machine with an IP address in the 192.168.128.0/24 range, telnet to 192.168.128.101. There is no password needed. Send a newline (Return or Enter key) and you'll probably be greeted by a menu. If no menu appears, send a ? and a newline to the EMM.

Crashing an EMM over the network

$ sudo nmap -O -p 1- 172.16.10.116
Starting Nmap 7.93 ( https://nmap.org ) at 2025-05-22 13:12 UTC

and wait forever. Power cycling may be required to bring it back to life at this point.