OpenGear IM4248 Infrastructure Manager
Jump to navigation
Jump to search
The Opengear IM4248 Infrastructure Manager is a network console server with 48 8P8C modular serial ports located on the front
They are three variations on the serial port pinout available: "Opengear Classic/Avocent/Equinox," and "Avocent/Cyclades," and "Cisco." The unit I have is an Opengear Classic model.
Serial port pinout
pin | signal name |
---|---|
1 | RTS (request to send) |
2 | DSR (data set ready) |
3 | DCD (data carrier detect) |
4 | RxD (receive data) |
5 | TxD (transmit data) |
6 | GND (signal ground) |
7 | DTR (data terminal ready) |
8 | CTS (clear to send) |
A cable for the common Cisco console port
Cisco pin | Cisco side signal name | wire color | Opengear classic side signal name | Opengear classic pin |
---|---|---|---|---|
1 | no connect | - | RTS | 1 |
2 | DTR | white/orange | DSR | 2 |
3 | TxD | orange | RxD | 4 |
5 | GND | white/green | GND | 6 |
6 | RxD | white/blue | TxD | 5 |
7 | DSR | blue | DTR | 7 |
8 | no connect | - | CTS | 8 |